Charging Modes

The meaning of the value of the event type CHARGING_MODE differs due to selected Source type. This means for example the CHARGING_MODE value 5 for a CAR_CHARGER means "Minimal and Solar" where as the CHARGING_MODE value 5 for a HEAT_PUMP means "noControl".

Car

Event type: CHARGING_MODE

Source type: CAR_CHARGER

Charging Mode

Below are the charging modes which can be set for a EV Charger to describe how the car currently will be charged.

IDModeDescription
0

Fast charge

Charge with maximum possible power.

1

Only solar

Only charge if sufficient solar power is available. The power is regulated depending on the available solar power.

2

Solar and tariff optimized

Charge during the day if sufficient solar power is available. If the battery is not full at the start of low tariff hours, charging occurs with maximum possible power.

3

Do not charge

Do not charge the car.

4

Constant current

Charge with a constant current.

5

Minimal and solar

Charges with a minimum current (mostly 6A and single-phase, if supported). If there is a solar power surplus, this is used on top.

6

Minimum charge quantity

Charge minimum quantity

7

Charging Target (%)

Charge until target percentage is reached

Battery

Event type: CHARGING_MODE

Source type: BATTERY

Charging Mode

Below are the charging modes which can be set for a BATTERY to describe how the BATTERY currently will be charged.

IDMode
0

Passive

1

Active

2

Charge

3

Discharge

4

OFF

Heat Pump

Event type: CHARGING_MODE

Source type: HEAT_PUMP

Charging Mode

Below are the charging modes which can be set for a HEAT_PUMP to describe how the HEAT_PUMP currently will be charged.

IDMode
0

No Mode

1

ON

2

OFF

3

Only Solar

4

Solar & Tariff optimized

5

No Control

Last updated